• Kyn28-12 Indoor AC Metal-Enclosed Switchgear
  • Kyn28-12 Indoor AC Metal-Enclosed Switchgear
  • Kyn28-12 Indoor AC Metal-Enclosed Switchgear
  • Kyn28-12 Indoor AC Metal-Enclosed Switchgear
  • Kyn28-12 Indoor AC Metal-Enclosed Switchgear
  • Kyn28-12 Indoor AC Metal-Enclosed Switchgear

Kyn28-12 Indoor AC Metal-Enclosed Switchgear

Certification: CCC, ISO9001
Shell Material: Stainless Steel
Voltage Level: High Voltage
Installation: Fixed
Structure: Cabinet
Current: AC
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
KYN28-12
Transport Package
Plywood Case
Trademark
Dechun
Origin
Changzhou, Jiangsu, China
HS Code
8537209000
Production Capacity
30000 PCS/Year

Product Description

KYN28-12 Indoor Metel-Closed Switchgear

Kyn28-12 Indoor AC Metal-Enclosed Switchgear

KYN28-12-Indoor AC metal-enclosed armored move switching devices (referred to as middle Cabinet) applied to 3.6~12KV three-phase AC 50Hz power grid, as the acceptance and distribution of electrical energy, and the exercise of control, monitoring and protection purposes.The product configuration VD4/VDM6/BP1/BP2/VS1 type of vacuum circuit breaker as a main switch, compact structure, superior performance and high reliability.

Features:
Anti harsh environment, anti condensation, frost, fog, salt contamination, corrosion resistance etc;
Compact structure, small size, easy to install;
Modular design, flexible expansion;
Smart grid compatible, optional automation terminal, to meet the requirements of smart grid upgrade.

Applicable conditions:
Altitude:≤2000m
Ambienttemperature:-35ºC~+40ºC
Relative humidity
Daily average≤95%
Monthly average≤90%
Seismic capacity: 8 degrees 

Kyn28-12 Indoor AC Metal-Enclosed Switchgear
No Item Unit Parameter
1 Rated voltage KV 3.6,7.2/12
2 Rated frequency Hz 50
3 Rated current of breaker A 630,1250,1600,2000,2500,3150
4 Rated breaking active load current A 630,1250,1600,2000,2500,3150
5 Rated closed loop breaking current KA 20,25,31.5,40
6 Rated current under the cable charging breaking current KA 50,63,80,100
7 Rated short-circuit closing current(peak) KA 20,25,31.5,40
8 Rated short-circuit breaking current KA 50,63,80,100
9 Rated insulation level 1 min frequency withstand voltage Pole,the pole pair KV 24,32,42
break between KV 24,32,48
Lighting impulse withstand voltage(peak) Pole,the pole pair KV 40,60,75
break between KV 46,70,85
10 Degree of protection KV Enclosure IP4X,compartment,circuit breaker door open when IP2X

Kyn28-12 Indoor AC Metal-Enclosed Switchgear
Kyn28-12 Indoor AC Metal-Enclosed Switchgear
Kyn28-12 Indoor AC Metal-Enclosed Switchgear
Kyn28-12 Indoor AC Metal-Enclosed Switchgear
Kyn28-12 Indoor AC Metal-Enclosed Switchgear
Kyn28-12 Indoor AC Metal-Enclosed Switchgear


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
343
Year of Establishment
1999-04-16