| 10kv Technical Specification | C Module | F Module | V Module | CB Module | ||
| Load break switch | Switch fuse | Vacuum circuit breaker | Isolate/ earthing switch |
Vacuum circuit breaker | Isolate/ earthing switch |
|
| Rated voltage | 12 | 12 | 24 | 24 | 24 | 24 |
| Power frequence withstand voltage KV | 42/48 | 42/48 | 42/48 | 42/48 | 42/48 | 42/48 |
| Impulse withstand voltage KV | 75/85 | 75/85 | 75/85 | 75/85 | 75/85 | 75/85 |
| Rated current A | 630 | 125 | 630/1250 | 630/1250 | ||
| Closed loop A | 630 | |||||
| Off load cable charging A | 10 | |||||
| Rated active load drop-oput current A | 630 | 630 | ||||
| Earth fault breaking current A | 30 | 25 | ||||
| When earth fault frop-out current of cable charging A | 17.4 | |||||
| Short circuit drop-out current KA | 31.5 | 25 | ||||
| Making capacity KA | 50 | note | 63 | 63 | 63 | 63 |
| Short time current 4s KA | 20 | 20 | 25 | 20/25 | 20/25 | 20/25 |
| Transfer current A | 1750 | |||||
| Mechanical life times | 5000 | 5000 | 10000 | 3000 | 10000 | 3000 |
| 24kv Technical Specification | C Module | F Module | V Module | CB Module | ||
| Load break switch | Switch fuse | Vacuum circuit breaker | Isolate/ earthing switch |
Vacuum circuit breaker | Isolate/ earthing switch |
|
| Rated voltage | 24 | 24 | 24 | 24 | 24 | 24 |
| Power frequence withstand voltage KV | 65/79 | 65/79 | 65/79 | 65/79 | 65/79 | 65/79 |
| Impulse withstand voltage KV | 125/145 | 125/145 | 125/145 | 125/145 | 125/145 | 125/145 |
| Rated current A | 630 | 125 | 630 | |||
| Closed loop A | 630 | |||||
| Off load cable charging A | 10 | |||||
| Rated active load drop-oput current A | 31.5 | 630 | ||||
| Earth fault breaking current A | 63 | |||||
| When earth fault frop-out current of cable charging A | 43.3 | |||||
| Short circuit drop-out current KA | 20 note | 20 | 20 | 25 | ||
| Making capacity KA | 50 | 50 note | 50 | 50 | 63 | 63 |
| Short time current 4s KA | 20 | 20 | 20 | 25 | 25 | |
| Transfer current A | 1400 | |||||
| Mechanical life times | 5000 | 5000 | 10000 | 10000 | 10000 | 5000 |