Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker

Product Details
Customization: Available
Altitude: <=2000m
Ambient Temperature: -35c-+40c
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Full Customization
The supplier provides full customization services
R&D Capabilities
The supplier has 24 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (31)
  • Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker
  • Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker
  • Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker
  • Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker
Find Similar Products

Basic Info.

Model NO.
FLN36
Seismic Capacity
8 Degree Level
Transport Package
in Cartons
Trademark
DECHUN
Origin
Changzhou, Jiangsu, China
HS Code
85389000

Product Description


Technical Specification:
Item Unit Parameter
FLN36-12D/T630-20 FLN36-12D/T125-31.5
Rated voltage KV 12 12
Rated frequency Hz 50 50
Rated current A 630 630
1 min power frequency withstand voltage KV 42/48 42/48
Lighting impulse withstand voltage KV 75/85 75/85
5 min zero gauge rated power frequency withstand voltage KV 24 24
Rated thermal stability current(peak) KA 20/20  
Rated dynamic current(peak) KA 50/50  
Rated short circuit closing current KA 50/50  
Rated closed-loop breaking current A 630  
Rated active load breaking current A 630  
Rated cable charging breaking current A 10 10
Rated short circuit breaking current KA   31.5
Rated transfer current A   1750
Fuse type     XRNT-12KV/125A
Fuse strikes the output energy J   1±0.5
Mechanical life Time 5000/2000 5000/3000
The insulation distance betweent the live body and the ground mm >=125 >=125
SF6 Gas pressure (relative pressure at 20ºC) bar 0.4 0.4
Closing the same period ms <=2 <=2
Main circuit tesistance μΩ <=65 <=65

Product Description:
FLRN36-12 indoor AC high-voltage SF6 load break switch is an indoor switch equipment with 12kV rated voltage. The equipment adopts SF6 as gas arcing and insulation medium, including three phases which are opening , closing and earthing, It has the advantages of small volume, convenient installation and strong adaptability to the environmental.
Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker
Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker
Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker
Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker
Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker
Fln36-12kv, 630A Sf6 Gas-Insulated Load Break Switch Vacuum Circuit Breaker






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now